Mapping of OCPP ChargingPoint/Charging Station Statuses and Error Codes

This section explains the mapping between ChargePilot and VDV 463 charging point and charging station statuses as well as the error codes.

Mapping of Charging Points statuses

(ChargePilot®)
OCPP Charging Point status
(VDV 463 standard)
Charging Point status
  • available
Available
  • finishing
  • preparing
  • paused_ev
  • paused_lm
  • charging
  • suspended_ev
  • suspended_evse
Occupied
  • not supported yet by ChargePilot®
Reserved
  • unavailable
  • offline
Unavailable
  • error
  • unknown
Faulted

Mapping of Charging Points error codes

(ChargePilot®)
OCPP Charging Point error code
(VDV 463 standard)
Charging Point error code
  • NoError
-
  • EVCommunicationError
  • WeakSignal
CommunicationFailure
  • ConnectorLockFailure
  • GroundFailure
  • HighTemperature
  • LocalListConflict
  • OverCurrentFailure
  • PowerMeterFailure
  • PowerSwitchFailure
  • ReaderFailure
  • ResetFailure
  • UnderVoltage
  • OverVoltage
UsageFailure
  • InternalError
OtherChargingPointFailure
  • Unknown
  • OtherError
NoFaultKnown

Mapping of Charging Station statuses

(ChargePilot®)
OCPP Charging Station error code
(ChargePilot®)
Charging Station status
(VDV 463 standard)
Charging Station status
NoErrorOnlineAvailable
all other error codesFaulted or OnlineFaulted
last reported status longer than minute agoOfflineUnavailable

Mapping of Charging Station error codes

(ChargePilot®)
OCPP Charging station error code
(VDV 463 standard)
Charging station error code
  • NoError
-
  • EVCommunicationError
  • WeakSignal
CommunicationFailure
  • GroundFailure
  • PowerMeterFailure
  • PowerSwitchFailure
  • HighTemperature
  • OverVoltage
  • UnderVoltage
  • OverCurrentFailure
ElectricalOperationFailure
  • LocalListConflict
ConfigurationFailure
  • ConnectorLockFailure
  • InternalError
  • ReaderFailure
  • ResetFailure
OtherChargingStationFailure
  • OtherError
  • Unknown
NoFaultKnown